
Certified annual NFPA 80 fire door inspections, rolling fire door drop testing, same-visit deficiency repair, and AHJ-ready certification — performed statewide by AAADM Certified Inspector #150572.
Our team is trained and certified to provide expert repairs, installations, and maintenance for all your favorite brands.
Ready to upgrade your commercial doors? Our experts are standing by to provide you with a comprehensive quote and professional consultation.
Fill out the form below and we'll get back to you within 2 hours.
All of Florida
Licensed & Insured Statewide
Monday - Friday: 8:00 am - 4:30 pm
Emergency service 24/7
5.0 Star Rating
50+ Reviews
Licensed & Insured
Florida Certified
24/7 Emergency
Rapid Response
NFPA 80 requires every fire-rated door assembly to be inspected and tested annually — including a drop test on rolling fire doors. Florida fire marshals, AHJs, and insurance carriers enforce it. Paratec inspects, repairs, certifies, and documents your fire doors in one visit.
Our team performs the full NFPA 80 inspection and testing procedure on rolling, swinging, and counter-shutter fire door assemblies, then corrects deficiencies and issues the certification record your Authority Having Jurisdiction requires.
Florida State License: SCC131152916•AAADM Inspector: #150572
One certified team to inspect, drop-test, repair, and certify every fire-rated door in your facility — with the documentation your AHJ, fire marshal, and insurer require.
Our experts are ready to assess your needs and recommend the perfect solution for your commercial door requirements.
Every type of fire-rated door assembly is inspected to the exact NFPA 80 procedure — and most deficiencies are corrected the same day so the door leaves certified.
NFPA 80 §5.2 requires annual drop testing of every rolling fire door and fire shutter. We test the automatic-closing and reset function, document the result, and repair governors, springs, and releases that fail.

Fire-rated swing doors are inspected per NFPA 80 §6.4 — gap and clearance measurement, self-closing and latching verification, label legibility, and hardware (closers, hinges, panics, smoke seals).

Failed clearances, painted-over labels, field modifications, missing hardware, and disconnected releases are corrected and the assembly is recertified — restoring the fire rating and your compliance.

A repeatable, documented NFPA 80 process that leaves every rated opening tested, corrected, and certified.
We identify and log every fire-rated door in the facility — rolling, swinging, and counter shutters — so nothing is missed during survey.
We confirm each door carries a legible, unaltered UL/WH fire label and that the rating matches the wall assembly and opening.
Rolling fire doors are drop-tested per NFPA 80 §5.2; swing doors are checked for self-closing, positive latching, and proper clearances per §6.4.
Closers, hinges, latches, panic devices, coordinators, smoke seals, and gap/clearance measurements are all verified against NFPA 80.
Most deficiencies are repaired on the same visit; anything requiring OEM parts is quoted with lead times so the door is recertified fast.
You receive a written report with photos, a ranked deficiency log, corrective actions, and the AHJ-ready certification record.
Every rated opening is checked against the published NFPA 80 criteria below.
If your building has fire-rated openings, NFPA 80 annual inspection applies. These facilities are cited most often.
Joint Commission and CMS surveys require annual fire door inspection with documented deficiency tracking in patient-care facilities.
Corridor, stairwell, and mechanical-room fire doors must pass annual NFPA 80 inspection to protect egress paths.
Rolling fire doors and shutters between fire compartments require annual drop testing — a common OSHA and AHJ citation area.
Offices, retail, and mixed-use buildings need certified fire doors on stairwells, corridors, and demising walls for life-safety compliance.
Need new rated doors too? Explore our commercial fire-rated doors and full commercial door inspection services.
Real feedback from Florida businesses who trust Paratec Door Solutions
“The techs are some of the best in the industry, the office personnel is quick to respond, even afterhours because gates break day and night, and their pricing is extremely competitive. They will always be the service provider I call when in need of help! Thanks Paratec!!”
“Quick response time and quality work. The tech, Jeff, was very polite and professional. Will definitely use them again should the need arise. I would recommend them to anyone needing garage door repair or replacement.”
Experience the same exceptional service that earned us these 5-star reviews. Get your free consultation today.
Annual fire door inspections performed to the exact NFPA 80 procedure — the standard your AHJ, fire marshal, and insurance carrier require every 12 months.
We don't just find deficiencies — most are corrected on the same visit so your fire doors leave the inspection certified and code-compliant.
Every inspection ends with a written report, photos, labeling verification, and a deficiency log formatted for your Authority Having Jurisdiction.
On-site fire door inspection and certification anywhere in Florida — with same-day repair on most deficiencies thanks to stocked trucks.
Join hundreds of satisfied customers who trust Paratec Door Solutions for their commercial door needs.
Fire marshal visit coming up? Insurance audit or Joint Commission survey scheduled? Get your fire doors inspected, drop-tested, repaired, and certified by a certified team before deficiencies become citations.
Paratec is your single AAADM-certified provider for NFPA 80 fire door inspections and ANSI/BHMA A156.10 / A156.19 automatic door inspections — one team, one report, statewide.
Get instant answers to the most common questions about our fire door inspection & certification services. Can't find what you're looking for? We're here to help.
NFPA 80 requires fire door assemblies to be inspected and tested at least once every 12 months (annually), and after any repair or modification. Rolling fire doors and fire shutters additionally require an annual drop test to verify automatic closing. Newly installed fire doors must also receive an acceptance test. Florida AHJs, fire marshals, and insurance carriers enforce these annual inspection requirements.
A drop test is the NFPA 80 §5.2 procedure for rolling fire doors and fire shutters. The door is released as it would be in a fire (via the automatic-closing device), and the inspector confirms it fully closes at the correct governed speed and then resets properly. It must be performed annually and documented. Paratec drop-tests your rolling fire doors, records the result, and repairs any governor, spring, or release that fails.
Certification means the fire door assembly has been inspected against NFPA 80, any deficiencies have been corrected, and it is documented as compliant. Our process covers label verification, clearance and gap measurement, self-closing and latching tests, drop testing for rolling doors, hardware inspection, deficiency correction, and a written AHJ-ready report with photos and code references confirming the door meets its fire rating.
Yes. Paratec performs NFPA 80 fire door inspections and is an AAADM Certified Inspector (#150572). Our technicians are trained on the full NFPA 80 inspection and testing procedure for rolling, swinging, and counter-shutter fire door assemblies, and we hold Florida State License SCC131152916.
The most frequently cited NFPA 80 deficiencies are: painted-over or missing/illegible labels, excessive clearance gaps around the door, doors that don't self-close or positively latch, field modifications and unfilled holes, missing or broken hardware (closers, hinges, coordinators), blocked or wedged-open doors, and rolling fire doors that fail the drop test. We correct most of these on the same visit.
Yes. Most fire door deficiencies — clearance adjustments, hardware replacement, closer and latch repair, label replacement, and release resetting — are corrected on the same visit because our trucks carry common NFPA 80 parts. Anything requiring OEM components is documented with a fixed-price quote and lead time so the door can be recertified quickly.
Absolutely. The majority of our fire door inspections are on doors installed by others. NFPA 80 inspection and certification are independent of the manufacturer or installer. We inspect and certify every major brand of rolling, swinging, and counter-shutter fire door, including Cornell, Cookson, Clopay, Wayne Dalton, and others.
Yes. Every inspection ends with a written report that includes per-opening results, photos, measurements, a ranked deficiency log with NFPA 80 citations, corrective actions taken, and a certification record. The documentation is formatted for your Authority Having Jurisdiction, fire marshal, insurance carrier, and (for healthcare) Joint Commission and CMS surveys.
Our expert team is ready to provide personalized answers and help you find the perfect solution for your fire door inspection & certification needs.
Paratec installs, repairs, and maintains every type of commercial and industrial door across Florida. Browse our full range of services and door types.
Paratec Door Solutions provides high-quality commercial and industrial door solutions across Florida. We offer installation, repair, and maintenance services for a wide range of door types.
LIC #SCC131152916
AAADM #150572
Monday - Friday: 8:00 am - 4:30 pm
Saturday: Closed
Sunday: Closed
Headquarters:
6626 Orchid Lake Rd, New Port Richey, FL 34653
Call Now - (844) 944-0362